TRILITE® CLR-10 is a macroporous polystyrenic based, thiol chelating resin, with functional groups designed for the selective removal of mercury, silver and for the recovery of precious metals from the industrial effluents (when existed as divalent cations) Selectivity of TRILITE® CLR-10 is Hg > Ag > Cu > Pb > Cd > Ni > Co > Fe > Ca > Na. For mercury recovery, the TRILITE® CLR-10 is able to remove that to below 5ppb. TRILITE® CLR-10 can be useful for problems where removal of ions Ag, Au, Pt, Pd is desired. Application may be found in different fields of chemical technology such as waste water treatment, recovery of precious metal from rinse waters in the electronic industries.
Physical and Chemical Propertieserties
Matrix
Styrene-DVB, Macroporous
Functional Group
Thiol
Ionic Form
H+
Total Capacity(eq/ℓ)
1.1↑
Moisture Retention(%)
38-48
Uniformity Coefficient
1.6
Recommended Operating Conditions
Operating Temp
60
pH Range
1 ~ 10 (recommended)
Bed Depth(mm)
1,000
Service Flow Rate(m/h)
5~15
Applications
TRILITE® CLR-10 is recommend for Mercury, Silver and Precious Metal Removal
All information contained in brochure is not absolute rather than relative one, created under the controlled environment by Samyang
Corporation. Therefore, Samyang Corporation has no legal responsibility with respect to any and all information provided in brochure.